適航指令資料庫查詢
CAA-2008-04-006
依據民用航空法規,航空器所有人或使用人除應遵守本國民航局所發布適航指令,亦應遵守航空器設計國之民航主管機關所通告之適航指令。
-
發布日期
- 2008/04/23
-
適用性說明
- Boeing Model 747-400F and -400 Series Airplanes.
-
型別
- Boeing Model 747-400F and -400 Series Airplanes
-
民航局AD編號
- CAA-2008-04-006
-
原發布國
- FAA
-
原AD編號
- 2008-08-25
-
生效日期
- 2008/05/27
-
主旨摘要
- To prevent water from entering the card file and damaging a circuit card. Failure of one or more of the 15 fuel system circuit cards in the card file could cause loss of fuel management, which could cause unavailability of fuel. Failure of one or more of the 35 fire detection circuit cards could cause a false message of a fire, or no message of a fire when there is a fire.
-
參考資訊(版本/ATA/SB)
- Boeing Alert Service Bulletin 747-25A3370, Revision 1(for Model 747-400F series airplanes);and Boeing Alert Service Bulletin 747-25A3526,(for Model 747-400 series airplanes).
-
存檔序號
- 97-04-008
-
專業分項
- Systems
-
產品類別
- Airplane
-
備註
-
檔案下載
-
1.本局早期(2012年前)所發布AD目前未提供檔案下載服務。如欲查詢,請自行連結原發布國民航主管機關網頁,再依”原AD編號”查詢。
2.我國目前所引進航空產品原發布國民航主管機關網頁聯結如下:
Canada、EASA、FAA、Israel、JapanCAB、UK、Brazil、CAA-CZ