跳到主要內容區塊
熱門關鍵字:飛航安全空拍機既時航班
menu

search
民航業務

適航指令資料庫查詢

CAA-2006-05-004B(已有後續修訂版)

依據民用航空法規,航空器所有人或使用人除應遵守本國民航局所發布適航指令,亦應遵守航空器設計國之民航主管機關所通告之適航指令。

發布日期
2006/05/30
適用性說明
CTT Systems AB Zonal Drying System, known to be installed in, but not limited to, Airbus A330-243 and A330-322; Boeing 737-700, 737-800, 747-400, and 767-300 series; Bombardier CL-600-2B19; and McDonnell Douglas MD-11 series aeroplanes.
型別
CTT Systems AB Zonal Drying System, known to be installed in, but not limited to, Airbus A330-243 and A330-322; Boeing 737-700, 737-800, 747-400, and 767-300 series; Bombardier CL-600-2B19; and McDonnell Douglas MD-11 series aeroplanes.
民航局AD編號
CAA-2006-05-004B(已有後續修訂版)
原發布國
EASA
原AD編號
2006-0140-E
生效日期
2006/05/25
主旨摘要
Air Conditioning - Zonal Drying System Deactivation
參考資訊(版本/ATA/SB)
ATA 21; Supersedes and cancels EASA AD 2006-0118R1-E(CAA-2006-05-004A); Ref. CTT Systems AB Information Letters IL06-01, IL06-02 issue 2 and IL06-03; and (for Lufthansa Technik STCs only) Lufthansa Technik AG Service Information Letter LHT 06-001, Revision IR
存檔序號
95-05-045
專業分項
Systems
產品類別
Airplane
備註
檔案下載

1.本局早期(2012年前)所發布AD目前未提供檔案下載服務。如欲查詢,請自行連結原發布國民航主管機關網頁,再依”原AD編號”查詢。

2.我國目前所引進航空產品原發布國民航主管機關網頁聯結如下:
CanadaEASAFAAIsraelJapanCABUKBrazilCAA-CZ

TOP